What was found
DURING INSPECTION, FOUND AFT CABIN FLOOR WET AREA, BS 987, RBL 43, SHEAR WEB UPPER SURFACE HAS CORROSION. MAINTENANCE REMOVED & REPLACED THE SHEAR WEB IAW SRM 51-40-02 AND DWG 147A5700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND AFT CABIN FLOOR WET AREA, BS 987, RBL 43, SHEAR WEB UPPER SURFACE HAS CORROSION. MAINTENANCE REMOVED & REPLACED THE SHEAR WEB IAW SRM 51-40-02 AND DWG 147A5700.