What was found
DURING INSPECTION, FOUND CORROSION ON SUPPORT ZEE STRINGER 25R, LOCATED BETWEEN BS 727 & 767 AT AFT CARGO BAY. MAINTENANCE REPLACED THE SUPPORT ZEE IAW SRM 51-40-02, 51-10-02 ITEM 9, AND DWG 146A7500.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON SUPPORT ZEE STRINGER 25R, LOCATED BETWEEN BS 727 & 767 AT AFT CARGO BAY. MAINTENANCE REPLACED THE SUPPORT ZEE IAW SRM 51-40-02, 51-10-02 ITEM 9, AND DWG 146A7500.