What was found
RIGHT NR 2 ENGINE O/B CORE COWLING LWR AFT LATCH BLOCK FITTING AND ATTACH STRUCTURE IS GOUGED. FITTING BLOCK IS LOOSE AND FASTENERS LOOSE. BLENDED GOUGE ON RT ENGINE O/B CORE COWL LOWER AFT LATCH BLOCK FITTING AND STRUCTURE. BEYOND LIMITS OF SRM 54-41-02 DETAIL VIII. HFEC INSP FOUND A CRACK AT AFT LOWER FASTENER HOLE OF LONGERON. REPLACED LONGERON IAW DWG 314N3201 PT 314N3210U6. MATERIAL LOSS ON BLOCK FITTING ORIGINAL. BEYOND ALLOWABLE LIMITS OF SRM 54-41-02 FIG 1. REPLACED BLOCK FITTING IAW BAC DWG 314N3210. PN 314T1339-16.