What was found
DURING INSPECTION, FOUND THE E & E BAY BILGE AREA AFT OF ACCESS DOOR, STRINGER 28L AND SPLICE FROM BS 351 - 380 HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED THE STRINGER IAW SRM 53-00-03, REP 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND THE E & E BAY BILGE AREA AFT OF ACCESS DOOR, STRINGER 28L AND SPLICE FROM BS 351 - 380 HAS MULTIPLE AREAS OF CORROSION. MAINTENANCE REPAIRED THE STRINGER IAW SRM 53-00-03, REP 1.