What was found
AFT CARGO BAY RT SIDEWALL PANEL AT BS 1520, METAL STRIP CORRODED AROUND FASTENER HOLES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM. FABRICATED NEW CAP STRIP TREATED AND PRIMED THE BOTTOM IAW SRM, AMM 51-21, AND DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CARGO BAY RT SIDEWALL PANEL AT BS 1520, METAL STRIP CORRODED AROUND FASTENER HOLES. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM. FABRICATED NEW CAP STRIP TREATED AND PRIMED THE BOTTOM IAW SRM, AMM 51-21, AND DWG.