What was found
FAIRING SUPPORT STRUCTURE FOR PANEL 191AL 29" AFT OF L/E AND LBL 5 HAS CORROSION. REMOVED CORROSION FROM PANEL 191AL FAIRING SUPPORT STRUCTURE 29" AFT OF L/E AT LBL 5 ORIGINAL MATERIAL THICKNESS .063", LOSS OF .009", WITH .054" REMAINING IS OUT OF LIMITS IAW SRM 53-00-71. REPAIRED SUPPORT STRUCTURE IAW PRI ER/A 557234-14 REV'S 0-1 AND ER/A 557234-14 REV ORIGINAL FOR EXTENDED LIMITS.