What was found
CORROSION AND ELONGATED HOLE ON FLOOR SUPPORT STA Y= 180, Y=197, Y=200 BTW X=-22 TO X=-54. REPAIRED PER SRM 51-30-2 AND 51-30-5.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AND ELONGATED HOLE ON FLOOR SUPPORT STA Y= 180, Y=197, Y=200 BTW X=-22 TO X=-54. REPAIRED PER SRM 51-30-2 AND 51-30-5.