What was found
ELONGATE HOLES ON FUEL TANKS ACCESS PLATES 520LB, 141AL, AND 141AR. ACCESS PLATES WERE REWORKED AND FOUND 6 HOLES OUT OF LIMITS PER SRM 57-10-01-2R B CONDITION II. FABRICATED BUSHINGS PER SRM 57-10-01-2R B CONDITION II(1), (3) (D) FOR 520 LB, AND SRM 57-10-01-2R B CONDITION II (1) (2), (D) FOR 141AL AND 141AR WITH AN INTERFERENCE FIT OF 0.0005" TO 0.0015". THE BUSHINGS WERE INSTALLED ON ACCESS PLATE 141AL (4E/A), 141AR (1E/A), AND 520LB (1E/A) PER SRM 57-10-01-2R-2.