As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK ON CHANNEL AT FLOOR PANELS NR 389G AND 465A. FLOOR PANEL 389G AND 465A WAS STOP DRILLED THE END OF CRACK WITH 0.250" PER SRM 53-05 FIG 131B. DOUBLER (2) WAS FABRICATED AND INSTALLED PER SRM 51-10-2 AND 53-05 FIG 131B AND 51-30-2.