What was found
DENT AND SCRAPE IN THE RT SKIN AT BS 577 - 580, BETWEEN STRINGERS 25R - 26R. CLEANED AREA. ACCOMPLISHED HFEC INSPECTION IAW SRM 53-01-01 & AMM NDT SPM 06.10.01.001. NO CRACKS INDICATED. THE DENT WS FOUND TO BE 0.092 DEEP BY 2 INCHES WIDE. IAW SRM 53-01-01, CONDITION 1C, INSPECTION WAS PERFORMED AND INTERNAL DOUBLER EXISTING ON AREA IAW SRM 53-01-01-1A. THE AREA WAS REPAIRED IAW ETI-17-17-065, REV 3, AND ER/A 558133-14, REV ORIGINAL.