What was found
DURING INSPECTION FOUND E&E BAY INTERCOSTAL CORRODED STATION 320 TO 325 STR 23L UPPER SIDE. MAINTENANCE REMOVE AND REPLACE INTERCOSTAL IAW DWG 141A8131 AND IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION FOUND E&E BAY INTERCOSTAL CORRODED STATION 320 TO 325 STR 23L UPPER SIDE. MAINTENANCE REMOVE AND REPLACE INTERCOSTAL IAW DWG 141A8131 AND IAW SRM 51-40-02.