What was found
CORROSION ON CUSP WEB UPPER & LOWER SURFACES BETWEEN RBL 54 TO 60, BS 622 TO 624 AND BS 629 TO 630. THE DAMAGE WAS REMOVED IAW SRM 53-00-55-2R, FIG 216. HFEC INSPECTION WAS ACCOMPLISHED AND NO CRACKS WERE FOUND AFTER THE DAMAGED WAS REMOVED IAW NDT SPM 06-10-01.001. THE CUSP WEB WAS REPAIRED SRM 53-00-55-2R-4, FIG 216, SHEET 1.