What was found
CORROSION ON CUSP WEB MEMBRANE UPPER LWR SURFACE BTW X=-54 TO X=-60 AND STAY=552 TO STAY=553 AT CAB PAX RT SIDE. DAMAGE WAS REMOVED PER SRM 53-00-55-2R REPAIR 4. HFEC WAS ACCOMPLISHED ON EDGES OF TRIMMED AREA, NO CRACKS WERE FOUND PER NDTSPM PART 6, 06-10-01.001. REPAIR PARTS WERE FABRICATED PER SRM 53-00-55-2R-4- FIG 209, REPAIR PARTS WERE INSTALLED PER SRM 53-00-55-2R-4- FIG 209 AND SRM 51-41-02-OG, CIC WAS APPLIED PER SRM 51-10-04 PAR 37.