What was found
DURING INSPECTION, THE R2 DOOR EMERGENCY TRIGGER FOUND FRACTURED. REMOVED AND REPLACED THE TRIGGER IAW AMM 52-11-32. OPS CHECK AND ADJUSTMENT PERFORMED ON AMDS 5211-9001-2R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, THE R2 DOOR EMERGENCY TRIGGER FOUND FRACTURED. REMOVED AND REPLACED THE TRIGGER IAW AMM 52-11-32. OPS CHECK AND ADJUSTMENT PERFORMED ON AMDS 5211-9001-2R.