What was found
CABIN FLOOR STRUCTURE, U CHANNEL BETWEEN STATIONS 1640-1660 AT BL 0 CORRODED. BLENDED CORROSION IAW SRM 51-10-02, PG 12, PAR 15. MEASURED AND VERIFIED LIMITS IAW SRM 53-00-51, DETAIL III. OUT OF ALLOWABLE LIMITS. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM 51-40-02, PG 2, PAR 4, AND DWG 146N5230, REV -.