What was found
BS 680 - 690, LBL 50 UNDER FLOOR PANEL 640A HAS CORROSION AT FASTENER HOLES. REMOVED CORROSION IAW BS SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BS 680 - 690, LBL 50 UNDER FLOOR PANEL 640A HAS CORROSION AT FASTENER HOLES. REMOVED CORROSION IAW BS SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-30-15. REMOVED AND REPLACED THE ANGLE IAW SRM 51-40-02.