FLOORBEAM HAS CORROSION. REMOVED CORROSION AT BS 377, RBL 15. THE FLOORBEAM ANGLE, EVALUATED AREA, REMAINING MAT. .093, FABRICATED A NEW ANGLE AND INSTALLEDIAW SRM 53-00-51, 51-40-05 51-20-01, AMM 51-20-15, & ER/A 481634-14MA REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM HAS CORROSION. REMOVED CORROSION AT BS 377, RBL 15. THE FLOORBEAM ANGLE, EVALUATED AREA, REMAINING MAT. .093, FABRICATED A NEW ANGLE AND INSTALLEDIAW SRM 53-00-51, 51-40-05 51-20-01, AMM 51-20-15, & ER/A 481634-14MA REV A.