What was found
REPEAT, AIRBORNE, L AFT ENTRY DOOR EICAS MSG, QRH PROCEDURE ACCOMPLISHED. PRESSURIZATION NORMAL, ARMING HANDLE DOES MOVE UP A COUPLE INCHES WHEN AIRBORNE. INSPECTED DOOR AND FOUND DOOR OPERATING NML UNPRESSURIZED, BUT WHEN PRESSURIZED HAS VERY SOFT UNLATCHING. CHECKED LATCH CAM ROLLERS PER AMM 52-11-00-825-001, SECTION 2, AND ADJUSTED LATCH CAMS PER SECTION 3, FIG 504. DOOR NOW OPS NML PRESSURIZED AND UNPRESSURIZED.