What was found
SUNKEN FASTENER ON LT CABIN FLOOR CUSP WEB STA Y=662 BTW X=54 AND X=60 ALSO RT CUSP WEB ON STA Y=560 BTW X=-54 AND X=-60. REPAIR WAS ACCOMPLISHED PER SRM 53-00-55-2R-4 FIG 215.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SUNKEN FASTENER ON LT CABIN FLOOR CUSP WEB STA Y=662 BTW X=54 AND X=60 ALSO RT CUSP WEB ON STA Y=560 BTW X=-54 AND X=-60. REPAIR WAS ACCOMPLISHED PER SRM 53-00-55-2R-4 FIG 215.