What was found
CORROSION ON THE LT CUSP WEB UPPER & LOWER SURFACES, LBL 54 AND 60 FROM BS 418 TO 421. THE CUSP WEB WAS REPAIRED IAW SRM 53-00-55-2R-4, FIG 216. HFEC INSPECTION WAS ACCOMPLISHED ALONG THE TRIM LINE AND NO CRACKS WERE FOUND IAW NDT SPM 06-10-01.001.