What was found
CORROSION ON FLOORBEAM BS 218 BETWEEN LONGERONS 27L- 27R IN THE FWD CARGO BAY. A NEW FLOORBEAM ANGLE WAS FABRICATED AND REPLACED IAW SRM 53-14-1, FIG 7A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM BS 218 BETWEEN LONGERONS 27L- 27R IN THE FWD CARGO BAY. A NEW FLOORBEAM ANGLE WAS FABRICATED AND REPLACED IAW SRM 53-14-1, FIG 7A.