What was found
CORROSION ON FLOOR SUPPORTS STA Y=180 X=38 TO X=13 AND X=-9 TO -43 (2EA). CORROSION LEVEL 2. FLOOR SUPPORTS STA Y=180 X=38 TO X=13 AND X=-9 TO -43 WERE REPLACED PER SRM 51-40-08-0G AND 51-41-02-0G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORTS STA Y=180 X=38 TO X=13 AND X=-9 TO -43 (2EA). CORROSION LEVEL 2. FLOOR SUPPORTS STA Y=180 X=38 TO X=13 AND X=-9 TO -43 WERE REPLACED PER SRM 51-40-08-0G AND 51-41-02-0G.