What was found
PASSENGER CABIN FLOOR BS 1720, RBL 54 TERMINAL FITTING CORRODED AT THE END OF THE CREASE BEAM. REMOVED AND REPLACED THE FITTING IAW SRM 51-40-02, AND DWG 146N8722, REV N.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PASSENGER CABIN FLOOR BS 1720, RBL 54 TERMINAL FITTING CORRODED AT THE END OF THE CREASE BEAM. REMOVED AND REPLACED THE FITTING IAW SRM 51-40-02, AND DWG 146N8722, REV N.