What was found
DURING INSPECTION, FOUND THE ROW 24 SEAT MOUNTED EMERGENCY LIGHT INOPERATIVE. MAINTENANCE FOUND A BROKEN WIRE BEHIND THE SIDEWALL PANEL BY ROW 24. REPAIRED WIRE IAW SWP 20-90-03. OPS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.