As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON "Z" FLOOR SUPPORT BESIDE RT TIE TRACK BTW STA Y 427 TO 446 AT FWD CARGO COMPARTMENT. CORROSION LEVEL II. CORROSION ON "Z" FLOOR SUPPORT BESIDE RT TIE TRACK BTW STA Y 427 TO 446 AT FWD CARGO COMPARTMENT WAS REPLACED PER SRM 51-30-1, SRM 51-30-2 AND DWG 5936660 REV BZ.