What was found
DURING H CHECK, FLOOR SUPPORT AT FR 73-74, STATION Y2462 WAS FOUND CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-42-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING H CHECK, FLOOR SUPPORT AT FR 73-74, STATION Y2462 WAS FOUND CORRODED. REPLACED FLOOR SUPPORT PER SRM 51-42-11.