What was found
CALL SYSTEM CIRCUIT BREAKER POPPED, WILL NOT RESET. T/S PER WDM 33-21. FOUND DEBRIS SHORTING PSU AT ROW 28ABC. REMOVED DEBRIS. RESET C/B, SYSTEM OPS NRML.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CALL SYSTEM CIRCUIT BREAKER POPPED, WILL NOT RESET. T/S PER WDM 33-21. FOUND DEBRIS SHORTING PSU AT ROW 28ABC. REMOVED DEBRIS. RESET C/B, SYSTEM OPS NRML.