What was found
HORIZONTAL JACKSCREW COMPARTMENT RIGHT SIDE STA 1825 STR 3R TO STR 6R AT AFT END OF APU INLET DOOR HOUSING; SKIN INNER AND MIDDLE STRAPS ARE CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM. REPAIRED INNER AND MID STRAPS IAW SRM.