What was found
CORROSION LOWER FLOOR SUPPORT BETWEEN FRAMES 16 & 20 IN THE FWD GALLEY AREA, REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53112109, AND D53110339
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION LOWER FLOOR SUPPORT BETWEEN FRAMES 16 & 20 IN THE FWD GALLEY AREA, REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, DWG D53112109, AND D53110339