What was found
STRONG BURNING ODOR IN THE GALLEY, TURN OFF THE GALLEY POWER AND THE ODOR DISAPPEARED. FOUND THE FIRST CLASS LAVATORY SMOKE DETECTOR FAN MOTOR SEIZED AND EXTREMELY HOT. REPLACED THE FAN IAW AMM WDM 23-17.