What was found
L2 DOOR CUTOUT LOWER SILL CREASE BEAM CORRODED AT AFT GIRT BAR MOUNT FITTING. CORROSION REMOVED AND FOUND OUT LIMITS. INSTALLED NEW ANGLE ON THE CREASE BEAM IAW SRM 51-40-02, SRM 51-40-05, & DWG 143N8322, REV - .
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L2 DOOR CUTOUT LOWER SILL CREASE BEAM CORRODED AT AFT GIRT BAR MOUNT FITTING. CORROSION REMOVED AND FOUND OUT LIMITS. INSTALLED NEW ANGLE ON THE CREASE BEAM IAW SRM 51-40-02, SRM 51-40-05, & DWG 143N8322, REV - .