What was found
INITIAL INSPECTION. CORROSION ON FLOOR STRUCTURE SUPPORT BTW STA 160 TO STA 200, X=56, X=53 (2EA), X=44, X=24, AND X=14. LT SIDE. SUPPORTS WERE REPLACED PER SRM VOL II 51-30-02 AND 51-30-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INITIAL INSPECTION. CORROSION ON FLOOR STRUCTURE SUPPORT BTW STA 160 TO STA 200, X=56, X=53 (2EA), X=44, X=24, AND X=14. LT SIDE. SUPPORTS WERE REPLACED PER SRM VOL II 51-30-02 AND 51-30-05.