DURING INSPECTION, FOUND CORROSION ON WEB OF AFT CARGO BAY DOOR CUTOUT AT FLOOR STRUCTURE BETWEEN BS 793 - 847. MAINTENANCE REPLACED WEB IAW SRM 51-40-02 PAR. 5.