What was found
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SHIELD LOWER SURFACE BETWEEN BS 767 - 793, RBL 21. MAINTENANCE REPLACED THE SHIELD IAW SRM 51-40-02 AND DWG 146A8127, REV C.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SHIELD LOWER SURFACE BETWEEN BS 767 - 793, RBL 21. MAINTENANCE REPLACED THE SHIELD IAW SRM 51-40-02 AND DWG 146A8127, REV C.