What was found
CRACK WAS FOUND ON CUSP WEB HOLE STA Y=480 BTW X=-54/-60 DURING CORROSION REMOVAL AT CAB PAX. CRACK WAS BLENDED OUT PER SRM 53-00-00-1A FIG. 101 (ET) HFEC INSPECTION WAS PERFORMED ON CUSP WEB HOLE STA Y=480 BTW X=-54/-60 AT CAB PAX ON BLEND OUT. NO CRACKS WERE FOUND PER NDT SPM 06-10-01.001. BLENDED AREA WAS EVALUATED AS FOLLOW MAXIMUM MATERIAL REMOVED 0.060'' AND MAXIMUM ALLOWABLE MATERIAL REMOVED IT'S 0.100'' THEREFORE IT'S WITHIN LIMITS PER B717 SRM 53-00-00-1A FIG. 101 AREA WAS TREATED AND PAINTED PER B717 SRM 51-10-04-0G PAR 15, 21.