Service difficulty report · Connector · Airbus A350941

Difficulty date
March 6, 2018
Submitted
March 6, 2018
Operation
Air carrier
Aircraft
N506DN
Make and model
Airbus A350941
Aircraft serial
0175
Aircraft time
285 hours, 39 cycles
Part
Connector
Condition
Misinstalled
Location
Emergency Lights
Stage of operation
IN
How discovered
9
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING A SERVICE CHECK, FOUND THE L1 DOOR FLOOR LEVEL EMERGENCY LIGHT ON. THE COCKPIT SWITCH WAS IN ARM POSITION AND FLOOR ENTRY LIGHT WAS OUT. FOUND WIRES THE CONNECTOR TO THE EMERGENCY LIGHT AND EMERGENCY LIGHT WIRES PLUGGED INTO THE FLOOR ENTRY LIGHT. SWAPPED LIGHTS.