What was found
E/E BAY FWD LAVATORY SERVICING PANEL , CORROSION AROUND TUBE UNDER HEATING GASKET. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE SUPPORT & DOUBLER IAW SRM 51-40-02, PARA 4 & 9, AND DWG 141N8631, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
E/E BAY FWD LAVATORY SERVICING PANEL , CORROSION AROUND TUBE UNDER HEATING GASKET. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED THE SUPPORT & DOUBLER IAW SRM 51-40-02, PARA 4 & 9, AND DWG 141N8631, REV A.