What was found
HFEC SHOWED TWO CRACKS IN THE SKIN AT STRINGER 13AR, BS 1643. CUT OUT THE DAMAGE IAW PRI 566343-14, REV 2, STEP 2, AND COMPLIED WITH SRM 53-00-01, REPAIR 1, STEPS 1-3. PERFORMED HFEC OF THE CUTOUT IAW SRM 53-00-01, REPAIR 1, STEP 4. NO CRACKS INDICATED. REPAIRED IAW SRM 53-00-01, REPAIR 1, THRU STEP 11 AND PRI 566343-14, REV 4.