What was found
CRACKED FRAME ANGLE, FWD FACE BS 1022, BETWEEN LONGERONS 7L - 8L. THE FRAME ANGLE WAS REPLACED IAW SRM 51-41-02, AND 51-41-05 AND DWG 9912243, REV JS. HFEC INSPECTION WAS ACCOMPLISHED AND A CRACK WAS CONFIRMED IAW NDT SPM 06-10-01.001.