What was found
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT, BS 947.5 AND 967, RBL 58, REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 7C, AND DWG 147A5660, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND CORROSION ON THE FLOOR SUPPORT, BS 947.5 AND 967, RBL 58, REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, PAR 7C, AND DWG 147A5660, REV B.