What was found
DURING INSPECTION, FOUND CORROSION ON STRINGER 25L, BS 360+2, AFT EQUIPMENT ELECTRONIC COMPARTMENT. MAINTENANCE PERFORMED A PERMANENT REPAIR TO THE STRINGER BETWEEN BS 330.62 TO 360+6 IAW PRI 566497-14 REV 0, 1, 2, 3, 4, 5, AND ERA 566497-14, REV ORIGINAL.