What was found
DURING M CHECK, CABIN FR 79-80, Y1447.8 OUTBOARD FLOOR STRUCTURE FITTING FOUND CRACKED. REPLACED CAPLING PER SRM 51-42-11-001 AND DRAWING F53478040.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING M CHECK, CABIN FR 79-80, Y1447.8 OUTBOARD FLOOR STRUCTURE FITTING FOUND CRACKED. REPLACED CAPLING PER SRM 51-42-11-001 AND DRAWING F53478040.