As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT GENERATOR FAILURE WITH ASSOCIATED EICAS AMBER MESSAGE. FOLLOWED QRH PROCEDURES. RESET ONCE, NO LUCK, STARTED APU & CONTINUED ON TO DESTINATION. R & R THE C901 LEFT GEN CIRCUIT BREAKER IAW AMM 24-22. 927856. PERFORMED IDG ADJUSTMENT TEST IAW AMM 24-11-00. PERFORMED MULTIPLE TRANSFER & RECONFIGURATION, NO FAULTS.