What was found
MAIN DECK FLOORBEAM HAS A CRACKED VERTICAL INTERCOSTAL ATTACH ANGLE AT BS 660, RBL 48. REMOVED AND REPLACED ATTACH ANGLE IAW SRM 51-40-02, 51-30-01, AND DWG 143N5140, REV PL, REV BJ.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOORBEAM HAS A CRACKED VERTICAL INTERCOSTAL ATTACH ANGLE AT BS 660, RBL 48. REMOVED AND REPLACED ATTACH ANGLE IAW SRM 51-40-02, 51-30-01, AND DWG 143N5140, REV PL, REV BJ.