What was found
CORROSION FOUND ON THE FLOOR SUPPORT AT +Y1162 BETWEEN FRAMES 66 TO 67+15 INCHES IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 53472780.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT AT +Y1162 BETWEEN FRAMES 66 TO 67+15 INCHES IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-42-11 AND DWG 53472780.