What was found
R4 DOOR LOWER SILL UPPER SURFACE, FWD CHANNEL HAS CORROSION ON UPPER AND LOWER SURFACE AROUND FASTENER HOLES, BS 1660, RBL 71, THE CHANNEL WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-60-15, DETAIL VIII. REMOVED AND REPLACED THE CHANNEL IAW DWG 146N8722, REV B, AND SRM 51-40-02, PAR 7.