What was found
CORROSION FOUND ON THE BS 780 STRINGER 17L FLOOR TO SIDE WALL CLOSEOUT ANGLE. REPAIRED THE ANGLE IAW SRM 53-00-13, REPAIR 1, SRM 51-40-02, PARA 7, AND DWG 143N5520.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE BS 780 STRINGER 17L FLOOR TO SIDE WALL CLOSEOUT ANGLE. REPAIRED THE ANGLE IAW SRM 53-00-13, REPAIR 1, SRM 51-40-02, PARA 7, AND DWG 143N5520.