As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
WORN FRAME ON STA Y=1510 CANT BTW 4-8 HRS POSITION AT AFT ACCESSORIES COMPARTMENT. FRAME WAS BLENDED OUT PER SRM 53-01 FIG. 1, FRAME BTW 6 AND 8 POSITION FOUND WITHIN LIMITS. FRAME AT 4 HRS POSITION MINIMUM REMAINING THICKNESS IS 0.027" THEREFORE IT IS OUT OF LIMITS PER SRM 53-01 FIG 1 SHEET 3 AND WAS REPLACED PER SRM 51-30-2, 51-30-5.