What was found
WHILE PERFORMING INSPECTION OF NRC 100-175 FOUND FORWARD CARGO DOOR CUTOUT LOWER THRESHOLD PLATE WITH EXFOLIATED CORROSION STA 600. REMOVED FWD CARGO DOOR LOWER THRESHOLD PIT, PANEL SUPPORT BRACKET, AND FITTING ASSY TO GAIN ACCESS TO CORRODED FITTING IAW SRM 51-40-02 PAGES 2 AND 7. REMOVED CORRODED FITTING. INSTALLED NEW FITTING IAW SRM 51-40-02 PARA 70 PAGES 6 & 7. ACCESS RESTORATION ACCOMPLISHED ON NRC #100-299.