What was found
CORROSION FOUND ON THE FLOOR SUPPORT Y162.5, BETWEEN FRAMES 68 TO 69 IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, SRM 51-42-11 AND DWG 53472780, REV D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FOUND ON THE FLOOR SUPPORT Y162.5, BETWEEN FRAMES 68 TO 69 IN THE AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, SRM 51-42-11 AND DWG 53472780, REV D.